MAHLE OC 581 oil filter matches
Compare MAHLE OC 581 against compatible oil filters from other brands. Review thread size, gasket dimensions, height, valve behavior, and fitment notes before substituting. This is a research tool, not an automatic guarantee of fitment.
Before substituting: verify filter style, thread size or cartridge dimensions, gasket dimensions, height and clearance, bypass behavior, and your engine or equipment requirements.
Best equivalent matches
Select up to 4 filters, then click Compare to view their specs next to the searched filter. How matching is scored.
49 compatible options
| Specification | Searched filter MAHLE OC 581 Reference filter | FRAM PH3562Best Match SAFE | SAFE | SAFE | SAFE |
|---|---|---|---|---|---|
| Thread size | M20x1.5 | M20X1,5 | M20x1.5 | M20X1,5 | M20X1,5 |
| Gasket OD | 71 mm | 71 mm | 72 mm | 72 mm | 72 mm |
| Gasket ID | 62.5 mm | 62 mm | 63 mm | 62 mm | 62 mm |
| Can OD | 80 mm | 78 mm | 82.14 mm | 76 mm | 76 mm |
| Height | 100 mm | 93 mm | 103.4 mm | 90 mm | 90 mm |
| Internal bypass valve | Yes | Yes | Yes | Yes | Yes |
| Bypass PSID | 14 | 12 | 16 | 12 | 12 |
| Anti-drainback valve | Yes | Yes | Yes | Yes | Yes |
Other suitable matches
Sorted best-fit first. Dot rating summarizes relative fit without exposing the raw score. How matching is scored.
6
Closest known dimensional difference: height -15 mm. Verify application-specific requirements before substituting.
7
Closest known dimensional difference: height -11 mm. Verify application-specific requirements before substituting.
8
Closest known dimensional difference: height -13.6 mm. Verify application-specific requirements before substituting.
9
Closest known dimensional difference: height -12 mm. Verify application-specific requirements before substituting.
10
Closest known dimensional difference: gasket ID -0.5 mm. Verify application-specific requirements before substituting.
11
Closest known dimensional difference: height -21 mm. Verify application-specific requirements before substituting.
12
Closest known dimensional difference: height -20.5 mm. Verify application-specific requirements before substituting.
13
Closest known dimensional difference: height +5 mm. Verify application-specific requirements before substituting.
14
Closest known dimensional difference: height -14.3 mm. Verify application-specific requirements before substituting.
15
Closest known dimensional difference: height -18.2 mm. Verify application-specific requirements before substituting.
16
Closest known dimensional difference: height +20 mm. Verify application-specific requirements before substituting.
17
Closest known dimensional difference: height -15 mm. Verify application-specific requirements before substituting.
18
Closest known dimensional difference: height -21 mm. Verify application-specific requirements before substituting.
19
Closest known dimensional difference: gasket ID -1.5 mm. Verify application-specific requirements before substituting.
20
Closest known dimensional difference: gasket ID -1.5 mm. Verify application-specific requirements before substituting.
21
Closest known dimensional difference: height -35.2 mm. Verify application-specific requirements before substituting.
22
Closest known dimensional difference: height +12 mm. Verify application-specific requirements before substituting.
23
Closest known dimensional difference: height +5.7 mm. Verify application-specific requirements before substituting.
24
Closest known dimensional difference: height +5.7 mm. Verify application-specific requirements before substituting.
25
Closest known dimensional difference: height +5.7 mm. Verify application-specific requirements before substituting.
26
Closest known dimensional difference: height +21 mm. Verify application-specific requirements before substituting.
27
Closest known dimensional difference: height -15 mm. Verify application-specific requirements before substituting.
28
Closest known dimensional difference: height -15 mm. Verify application-specific requirements before substituting.
29
Closest known dimensional difference: height -20 mm. Verify application-specific requirements before substituting.
30
Closest known dimensional difference: height -1.6 mm. Verify application-specific requirements before substituting.
31
Closest known dimensional difference: height -3.2 mm. Verify application-specific requirements before substituting.
32
Closest known dimensional difference: height -3.2 mm. Verify application-specific requirements before substituting.
33
Closest known dimensional difference: height -3.2 mm. Verify application-specific requirements before substituting.
34
Closest known dimensional difference: height -13.5 mm. Verify application-specific requirements before substituting.
35
Closest known dimensional difference: height +22.6 mm. Verify application-specific requirements before substituting.
36
Large bypass PSI mismatch: 12 psi
37
Closest known dimensional difference: height -20 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY38
Closest known dimensional difference: height +10.6 mm. Verify application-specific requirements before substituting.
39
Closest known dimensional difference: height -42.5 mm. Verify application-specific requirements before substituting.
40
Closest known dimensional difference: height -17.4 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY41
Closest known dimensional difference: height +22 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY42
Closest known dimensional difference: height +22.6 mm. Verify application-specific requirements before substituting.
43
Large bypass PSI mismatch: 16 psi
44
Large bypass PSI mismatch: 22 psi
1.0/5.0
RISKY45
Bypass presence unknown on one or both filters
46
Bypass presence unknown on one or both filters
47
Thread unknown on one or both filters
48
Thread unknown on one or both filters ยท Large bypass PSI mismatch: 7.8 psi
49
Thread unknown on one or both filters