CNH Industrial (Case IH) 1275229C1 oil filter matches
Compare CNH Industrial (Case IH) 1275229C1 against compatible oil filters from other brands. Review thread size, gasket dimensions, height, valve behavior, and fitment notes before substituting. This is a research tool, not an automatic guarantee of fitment.
Before substituting: verify filter style, thread size or cartridge dimensions, gasket dimensions, height and clearance, bypass behavior, and your engine or equipment requirements.
Best equivalent matches
Select up to 4 filters, then click Compare to view their specs next to the searched filter. How matching is scored.
42 compatible options
| Specification | Searched filter CNH Industrial (Case IH) 1275229C1 Reference filter | FRAM PH9763Best Match SAFE | SAFE | SAFE | SAFE |
|---|---|---|---|---|---|
| Thread size | M20x1.5 | M20X1,5 | M20X1,5 | M20X1,5 | M20X1,5 |
| Gasket OD | 71.4 mm | 72 mm | 71 mm | 72 mm | 72 mm |
| Gasket ID | 62.7 mm | 62 mm | 61 mm | 62 mm | 62 mm |
| Can OD | 68.25 mm | 68 mm | 68 mm | 76 mm | 76 mm |
| Height | 85.73 mm | 85 mm | 85 mm | 90 mm | 90 mm |
| Internal bypass valve | Yes | Yes | Yes | Yes | Yes |
| Bypass PSID | 11 - 14 | 12 | 12 | 12 | 12 |
| Anti-drainback valve | Yes | Yes | Yes | Yes | Yes |
Other suitable matches
Sorted best-fit first. Dot rating summarizes relative fit without exposing the raw score. How matching is scored.
6
Closest known dimensional difference: height -6.7 mm. Verify application-specific requirements before substituting.
7
Closest known dimensional difference: height -6.7 mm. Verify application-specific requirements before substituting.
8
Closest known dimensional difference: height -6.2 mm. Verify application-specific requirements before substituting.
9
Closest known dimensional difference: gasket OD -3.4 mm. Verify application-specific requirements before substituting.
10
Closest known dimensional difference: height -3.9 mm. Verify application-specific requirements before substituting.
11
Closest known dimensional difference: gasket ID -1.7 mm. Verify application-specific requirements before substituting.
12
Closest known dimensional difference: height +3.3 mm. Verify application-specific requirements before substituting.
13
Closest known dimensional difference: height +14.3 mm. Verify application-specific requirements before substituting.
14
Closest known dimensional difference: height +2.3 mm. Verify application-specific requirements before substituting.
15
Closest known dimensional difference: height -18.7 mm. Verify application-specific requirements before substituting.
16
Closest known dimensional difference: height -5.7 mm. Verify application-specific requirements before substituting.
17
Closest known dimensional difference: height +14.3 mm. Verify application-specific requirements before substituting.
18
Closest known dimensional difference: height +14.3 mm. Verify application-specific requirements before substituting.
19
Closest known dimensional difference: gasket OD -2 mm. Verify application-specific requirements before substituting.
20
Closest known dimensional difference: height +7.3 mm. Verify application-specific requirements before substituting.
21
Closest known dimensional difference: height -15.7 mm. Verify application-specific requirements before substituting.
22
Closest known dimensional difference: height -20.9 mm. Verify application-specific requirements before substituting.
23
Closest known dimensional difference: height +11.1 mm. Verify application-specific requirements before substituting.
24
Closest known dimensional difference: height +11.1 mm. Verify application-specific requirements before substituting.
25
Closest known dimensional difference: height +11.1 mm. Verify application-specific requirements before substituting.
26
Closest known dimensional difference: height +5.1 mm. Verify application-specific requirements before substituting.
27
Closest known dimensional difference: height -12.7 mm. Verify application-specific requirements before substituting.
28
Closest known dimensional difference: height +14.3 mm. Verify application-specific requirements before substituting.
29
Closest known dimensional difference: height +19.3 mm. Verify application-specific requirements before substituting.
30
Large bypass PSI mismatch: 7.5 psi
1.0/5.0
RISKY31
Large bypass PSI mismatch: 10.5 psi
32
Closest known dimensional difference: height +17.7 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY33
Closest known dimensional difference: height +19.9 mm. Verify application-specific requirements before substituting.
34
Closest known dimensional difference: height +19.9 mm. Verify application-specific requirements before substituting.
35
Closest known dimensional difference: height +19.9 mm. Verify application-specific requirements before substituting.
36
Closest known dimensional difference: height +24.9 mm. Verify application-specific requirements before substituting.
37
Closest known dimensional difference: height -5.7 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY38
Large bypass PSI mismatch: 7.5 psi
39
Bypass presence unknown on one or both filters
40
Bypass presence unknown on one or both filters
1.0/5.0
RISKY41
Thread unknown on one or both filters
42
Thread unknown on one or both filters ยท Large bypass PSI mismatch: 9.3 psi