FRAM PH5046 oil filter matches
Compare FRAM PH5046 against compatible oil filters from other brands. Review thread size, gasket dimensions, height, valve behavior, and fitment notes before substituting. This is a research tool, not an automatic guarantee of fitment.
Before substituting: verify filter style, thread size or cartridge dimensions, gasket dimensions, height and clearance, bypass behavior, and your engine or equipment requirements.
Best equivalent matches
Select up to 4 filters, then click Compare to view their specs next to the searched filter. How matching is scored.
43 compatible options
| Specification | Searched filter FRAM PH5046 Reference filter | FRAM PH9763Best Match SAFE | SAFE | SAFE | SAFE |
|---|---|---|---|---|---|
| Thread size | M20X1,5 | M20X1,5 | M20X1,5 | M20x1.5 | M20x1.5 |
| Gasket OD | 71 mm | 72 mm | 68 mm | 71.4 mm | 71 mm |
| Gasket ID | 61 mm | 62 mm | 62 mm | 62.7 mm | 61 mm |
| Can OD | 68 mm | 68 mm | 68 mm | 68.25 mm | 76 mm |
| Height | 85 mm | 85 mm | 85 mm | 85.73 mm | 85 mm |
| Internal bypass valve | Yes | Yes | Yes | Yes | Yes |
| Bypass PSID | 12 | 12 | 12 | 11 - 14 | 12 |
| Anti-drainback valve | Yes | Yes | Yes | Yes | Yes |
Other suitable matches
Sorted best-fit first. Dot rating summarizes relative fit without exposing the raw score. How matching is scored.
8
Closest known dimensional difference: height +15 mm. Verify application-specific requirements before substituting.
9
Closest known dimensional difference: height -5 mm. Verify application-specific requirements before substituting.
10
Closest known dimensional difference: height +15 mm. Verify application-specific requirements before substituting.
11
Closest known dimensional difference: height +15 mm. Verify application-specific requirements before substituting.
12
Closest known dimensional difference: height -6 mm. Verify application-specific requirements before substituting.
13
Closest known dimensional difference: height -6 mm. Verify application-specific requirements before substituting.
14
Closest known dimensional difference: height -15 mm. Verify application-specific requirements before substituting.
15
Closest known dimensional difference: height +3 mm. Verify application-specific requirements before substituting.
16
Closest known dimensional difference: height -3.2 mm. Verify application-specific requirements before substituting.
17
Closest known dimensional difference: height +4 mm. Verify application-specific requirements before substituting.
18
Closest known dimensional difference: height +8 mm. Verify application-specific requirements before substituting.
19
Closest known dimensional difference: height -18 mm. Verify application-specific requirements before substituting.
20
Closest known dimensional difference: height -5.5 mm. Verify application-specific requirements before substituting.
21
Closest known dimensional difference: gasket OD -1.6 mm. Verify application-specific requirements before substituting.
22
Closest known dimensional difference: height -5 mm. Verify application-specific requirements before substituting.
23
Closest known dimensional difference: height -12 mm. Verify application-specific requirements before substituting.
24
Closest known dimensional difference: height -20.2 mm. Verify application-specific requirements before substituting.
25
Closest known dimensional difference: height +20 mm. Verify application-specific requirements before substituting.
26
Large bypass PSI mismatch: 10 psi
27
Closest known dimensional difference: height +11.8 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY28
Closest known dimensional difference: height +11.8 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY29
Closest known dimensional difference: height +11.8 mm. Verify application-specific requirements before substituting.
30
Closest known dimensional difference: height +5.8 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY31
Closest known dimensional difference: height +15 mm. Verify application-specific requirements before substituting.
32
Large bypass PSI mismatch: 24 psi
1.0/5.0
RISKY33
Large bypass PSI mismatch: 8 psi
1.0/5.0
RISKY34
Closest known dimensional difference: height +18.4 mm. Verify application-specific requirements before substituting.
1.0/5.0
RISKY35
Closest known dimensional difference: height +20.7 mm. Verify application-specific requirements before substituting.
36
Closest known dimensional difference: height +20.7 mm. Verify application-specific requirements before substituting.
37
Closest known dimensional difference: height +20.7 mm. Verify application-specific requirements before substituting.
38
Closest known dimensional difference: height -27.5 mm. Verify application-specific requirements before substituting.
39
Large bypass PSI mismatch: 8 psi
40
Bypass presence unknown on one or both filters
41
Bypass presence unknown on one or both filters
1.0/5.0
RISKY42
Thread unknown on one or both filters
43
Thread unknown on one or both filters ยท Large bypass PSI mismatch: 9.8 psi