CNH Industrial (Case IH) 1275229C1 vs LUBER-FINER PH48: Oil Filter Compatibility
Compare CNH Industrial (Case IH) 1275229C1 and LUBER-FINER PH48 oil filters by compatibility, dimensions, thread size, gasket fit, bypass valve, anti-drainback valve status, and match confidence. Use this comparison as a fitment review, not as an automatic substitution guarantee. Both use a M20x1.5 thread.
Quick verdict
Closest known dimensional difference: height -6.7 mm. Verify application-specific requirements before substituting.
- Thread size is the first hard-fit check for any comparison of spin-on filters.
- Gasket OD and gasket ID are the most important seal-related dimensions.
- Height differences can matter for clearance even when thread and gasket fit appear close.
- Bypass and anti-drainback differences may be important, depending on the application.
CNH Industrial (Case IH) 1275229C1 and LUBER-FINER PH48 specifications
How matching is scored| Specification | CNH Industrial (Case IH) 1275229C1 | LUBER-FINER PH48 |
|---|---|---|
| Thread size | M20x1.5 | M20x1.5 |
| Gasket OD | 71.4 mm | 72 mm |
| Gasket ID | 62.7 mm | 62 mm |
| Can OD | 68.25 mm | 75.18 mm |
| Height | 85.73 mm | 78.99 mm |
| Internal bypass valve | Yes | Yes |
| Bypass PSID | 11 - 14 | 12 - 15 |
| Anti-drainback valve | Yes | Yes |
What matters in this specific comparison
Thread size matches: both are M20x1.5.
Gasket OD differs by 0.6 mm (CNH Industrial (Case IH) 1275229C1: 71.4 mm, LUBER-FINER PH48: 72 mm).
Gasket ID differs by 0.7 mm (CNH Industrial (Case IH) 1275229C1: 62.7 mm, LUBER-FINER PH48: 62 mm).
CNH Industrial (Case IH) 1275229C1 is 6.7 mm taller (CNH Industrial (Case IH) 1275229C1: 85.73 mm, LUBER-FINER PH48: 78.99 mm) -- check clearance before substituting.
Can OD differs by 6.9 mm (CNH Industrial (Case IH) 1275229C1: 68.25 mm, LUBER-FINER PH48: 75.18 mm).
Both open their bypass valve in a comparable range: CNH Industrial (Case IH) 1275229C1 at 11-14 psi, LUBER-FINER PH48 at 12-15 psi.
Open related filters
Before substituting, verify thread fit, gasket sealing dimensions, height clearance, bypass behavior, and anti-drainback requirements for your specific application.