WIX 57430 oil filter matches
Compare WIX 57430 against compatible oil filters from other brands. Review thread size, gasket dimensions, height, valve behavior, and fitment notes before substituting. This is a research tool, not an automatic guarantee of fitment.
Before substituting: verify filter style, thread size or cartridge dimensions, gasket dimensions, height and clearance, bypass behavior, and your engine or equipment requirements.
Best equivalent matches
Select up to 4 filters, then click Compare to view their specs next to the searched filter. How matching is scored.
60 compatible options
| Specification | Searched filter WIX 57430 Reference filter | Baldwin B74Best Match SAFE | SAFE | SAFE | SAFE |
|---|---|---|---|---|---|
| Thread size | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 |
| Gasket OD | 72.39 mm | 71.4 mm | 71.1 mm | 71.1 mm | 71.98 mm |
| Gasket ID | 62.53 mm | 62.7 mm | 62 mm | 62 mm | 62.53 mm |
| Can OD | 97.28 mm | 95.3 mm | 98.55 mm | 98.55 mm | 93.04 mm |
| Height | 100.3 mm | 100.8 mm | 98.55 mm | 98.55 mm | 96.82 mm |
| Internal bypass valve | Yes | Yes | Yes | Yes | Yes |
| Bypass PSID | 13 - 19 | 20 | 12 - 15 | 12 - 15 | 13 - 19 |
| Anti-drainback valve | Yes | Yes | Yes | Yes | Yes |
Other suitable matches
Sorted best-fit first. Dot rating summarizes relative fit without exposing the raw score.
8
Strong dimensional fit. Verify application-specific requirements before substituting.
9
Strong dimensional fit. Verify application-specific requirements before substituting.
10
Strong dimensional fit. Verify application-specific requirements before substituting.
11
Strong dimensional fit. Verify application-specific requirements before substituting.
12
Strong dimensional fit. Verify application-specific requirements before substituting.
13
Strong dimensional fit. Verify application-specific requirements before substituting.
14
Strong dimensional fit. Verify application-specific requirements before substituting.
15
Strong dimensional fit. Verify application-specific requirements before substituting.
16
Strong dimensional fit. Verify application-specific requirements before substituting.
17
Strong dimensional fit. Verify application-specific requirements before substituting.
18
Strong dimensional fit. Verify application-specific requirements before substituting.
19
Strong dimensional fit. Verify application-specific requirements before substituting.
20
Strong dimensional fit. Verify application-specific requirements before substituting.
21
Strong dimensional fit. Verify application-specific requirements before substituting.
22
Strong dimensional fit. Verify application-specific requirements before substituting.
23
Strong dimensional fit. Verify application-specific requirements before substituting.
24
Strong dimensional fit. Verify application-specific requirements before substituting.
25
Strong dimensional fit. Verify application-specific requirements before substituting.
26
Strong dimensional fit. Verify application-specific requirements before substituting.
27
Strong dimensional fit. Verify application-specific requirements before substituting.
28
Strong dimensional fit. Verify application-specific requirements before substituting.
29
Strong dimensional fit. Verify application-specific requirements before substituting.
30
Strong dimensional fit. Verify application-specific requirements before substituting.
31
Strong dimensional fit. Verify application-specific requirements before substituting.
32
Strong dimensional fit. Verify application-specific requirements before substituting.
33
Strong dimensional fit. Verify application-specific requirements before substituting.
34
Strong dimensional fit. Verify application-specific requirements before substituting.
35
Strong dimensional fit. Verify application-specific requirements before substituting.
36
Strong dimensional fit. Verify application-specific requirements before substituting.
37
Strong dimensional fit. Verify application-specific requirements before substituting.
38
Strong dimensional fit. Verify application-specific requirements before substituting.
39
Strong dimensional fit. Verify application-specific requirements before substituting.
40
Strong dimensional fit. Verify application-specific requirements before substituting.
41
Large bypass PSI mismatch: 8 psi
42
Large bypass PSI mismatch: 8 psi
43
Large bypass PSI mismatch: 16 psi
44
Strong dimensional fit. Verify application-specific requirements before substituting.
45
Strong dimensional fit. Verify application-specific requirements before substituting.
46
Strong dimensional fit. Verify application-specific requirements before substituting.
47
Strong dimensional fit. Verify application-specific requirements before substituting.
48
Strong dimensional fit. Verify application-specific requirements before substituting.
49
Strong dimensional fit. Verify application-specific requirements before substituting.
50
Large bypass PSI mismatch: 6.5 psi
51
Large bypass PSI mismatch: 6.5 psi
52
Large bypass PSI mismatch: 6.5 psi
53
Large bypass PSI mismatch: 6.5 psi
54
Strong dimensional fit. Verify application-specific requirements before substituting.
55
Strong dimensional fit. Verify application-specific requirements before substituting.
56
Strong dimensional fit. Verify application-specific requirements before substituting.
57
Strong dimensional fit. Verify application-specific requirements before substituting.
58
Strong dimensional fit. Verify application-specific requirements before substituting.
59
Strong dimensional fit. Verify application-specific requirements before substituting.
60
Candidate removes ADBV