MAHLE OC 236 oil filter matches
Compare MAHLE OC 236 against compatible oil filters from other brands. Review thread size, gasket dimensions, height, valve behavior, and fitment notes before substituting. This is a research tool, not an automatic guarantee of fitment.
Before substituting: verify filter style, thread size or cartridge dimensions, gasket dimensions, height and clearance, bypass behavior, and your engine or equipment requirements.
Best equivalent matches
Select up to 4 filters, then click Compare to view their specs next to the searched filter. How matching is scored.
60 compatible options
| Specification | Searched filter MAHLE OC 236 Reference filter | Bosch 3402Best Match SAFE | SAFE | SAFE | SAFE |
|---|---|---|---|---|---|
| Thread size | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 |
| Gasket OD | 72 mm | 71 mm | 71 mm | 72 mm | 71.1 mm |
| Gasket ID | 62 mm | 62 mm | 62 mm | 63 mm | 62 mm |
| Can OD | 92.96 mm | 94.01 mm | 93.73 mm | 93.98 mm | 93.73 mm |
| Height | 93.98 mm | 95.25 mm | 95.25 mm | 95.25 mm | 95.25 mm |
| Internal bypass valve | Yes | Yes | Yes | Yes | Yes |
| Bypass PSID | 12 - 15 | 8 - 16 | 12 - 15 | 8 - 16 | 12 - 15 |
| Anti-drainback valve | Yes | Yes | Yes | Yes | Yes |
Other suitable matches
Sorted best-fit first. Dot rating summarizes relative fit without exposing the raw score. How matching is scored.
23
Closest known dimensional difference: height +4.4 mm. Verify application-specific requirements before substituting.
24
Closest known dimensional difference: height +4.4 mm. Verify application-specific requirements before substituting.
25
Closest known dimensional difference: gasket OD -3 mm. Verify application-specific requirements before substituting.
26
Closest known dimensional difference: height +10.9 mm. Verify application-specific requirements before substituting.
27
Closest known dimensional difference: height +10.9 mm. Verify application-specific requirements before substituting.
28
Closest known dimensional difference: height -11.4 mm. Verify application-specific requirements before substituting.
29
Closest known dimensional difference: height +17.1 mm. Verify application-specific requirements before substituting.
30
Closest known dimensional difference: height +1 mm. Verify application-specific requirements before substituting.
31
Large bypass PSI mismatch: 18.5 psi
32
Large bypass PSI mismatch: 22.5 psi
33
Closest known dimensional difference: gasket OD -1 mm. Verify application-specific requirements before substituting.
34
Closest known dimensional difference: height -5.1 mm. Verify application-specific requirements before substituting.
35
Closest known dimensional difference: height -5.1 mm. Verify application-specific requirements before substituting.
36
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
37
Large bypass PSI mismatch: 10.5 psi
38
Closest known dimensional difference: height -6.9 mm. Verify application-specific requirements before substituting.
39
Closest known dimensional difference: height -15 mm. Verify application-specific requirements before substituting.
40
Closest known dimensional difference: height -12.5 mm. Verify application-specific requirements before substituting.
41
Closest known dimensional difference: height -7.9 mm. Verify application-specific requirements before substituting.
42
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
43
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
44
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
45
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
46
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
47
Closest known dimensional difference: height +5 mm. Verify application-specific requirements before substituting.
48
Closest known dimensional difference: height -3.2 mm. Verify application-specific requirements before substituting.
49
Closest known dimensional difference: height -4.3 mm. Verify application-specific requirements before substituting.
50
Closest known dimensional difference: height +6.3 mm. Verify application-specific requirements before substituting.
51
Closest known dimensional difference: height -17.8 mm. Verify application-specific requirements before substituting.
52
Closest known dimensional difference: height -7.5 mm. Verify application-specific requirements before substituting.
53
Candidate removes ADBV
54
Closest known dimensional difference: height -7.5 mm. Verify application-specific requirements before substituting.
55
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
56
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
57
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
58
Closest known dimensional difference: height -7.4 mm. Verify application-specific requirements before substituting.
59
Closest known dimensional difference: height -5.3 mm. Verify application-specific requirements before substituting.
60
Closest known dimensional difference: height -15.2 mm. Verify application-specific requirements before substituting.