Champ PH253 oil filter matches
Compare Champ PH253 against compatible oil filters from other brands. Review thread size, gasket dimensions, height, valve behavior, and fitment notes before substituting. This is a research tool, not an automatic guarantee of fitment.
Before substituting: verify filter style, thread size or cartridge dimensions, gasket dimensions, height and clearance, bypass behavior, and your engine or equipment requirements.
Best equivalent matches
Select up to 4 filters, then click Compare to view their specs next to the searched filter. How matching is scored.
60 compatible options
| Specification | Searched filter Champ PH253 Reference filter | Baldwin B163Best Match SAFE | SAFE | SAFE | SAFE |
|---|---|---|---|---|---|
| Thread size | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 |
| Gasket OD | 70.6 mm | 71.4 mm | 71.4 mm | 71.5 mm | 71.5 mm |
| Gasket ID | 62.2 mm | 62.7 mm | 62.7 mm | 62.5 mm | 62.5 mm |
| Can OD | 92.96 mm | 93.7 mm | 93.7 mm | 93.19 mm | 93.19 mm |
| Height | 93.98 mm | 98.4 mm | 98.4 mm | 95.81 mm | 95.81 mm |
| Internal bypass valve | Yes | Yes | Yes | Yes | Yes |
| Bypass PSID | 8 - 11 | 8 | 8 | 8 - 11 | 8 - 11 |
| Anti-drainback valve | Yes | Yes | Yes | Yes | Yes |
Other suitable matches
Sorted best-fit first. Dot rating summarizes relative fit without exposing the raw score. How matching is scored.
22
Closest known dimensional difference: height +17.1 mm. Verify application-specific requirements before substituting.
23
Closest known dimensional difference: height +10.9 mm. Verify application-specific requirements before substituting.
24
Closest known dimensional difference: height +10.9 mm. Verify application-specific requirements before substituting.
25
Closest known dimensional difference: gasket ID -1.2 mm. Verify application-specific requirements before substituting.
26
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
27
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
28
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
29
Closest known dimensional difference: height +4.6 mm. Verify application-specific requirements before substituting.
30
Closest known dimensional difference: height +4.6 mm. Verify application-specific requirements before substituting.
31
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
32
Closest known dimensional difference: height +16.2 mm. Verify application-specific requirements before substituting.
33
Closest known dimensional difference: height +12.5 mm. Verify application-specific requirements before substituting.
34
Closest known dimensional difference: height -6.7 mm. Verify application-specific requirements before substituting.
35
Large bypass PSI mismatch: 14.5 psi
36
Closest known dimensional difference: height -7.5 mm. Verify application-specific requirements before substituting.
37
Large bypass PSI mismatch: 22.5 psi
38
Large bypass PSI mismatch: 26.5 psi
39
Closest known dimensional difference: height -7.5 mm. Verify application-specific requirements before substituting.
40
Closest known dimensional difference: height -7.6 mm. Verify application-specific requirements before substituting.
41
Large bypass PSI mismatch: 6.5 psi
42
Large bypass PSI mismatch: 6.5 psi
43
Closest known dimensional difference: height +17.1 mm. Verify application-specific requirements before substituting.
44
Closest known dimensional difference: height -3.2 mm. Verify application-specific requirements before substituting.
45
Closest known dimensional difference: height -5 mm. Verify application-specific requirements before substituting.
46
Closest known dimensional difference: height +9.2 mm. Verify application-specific requirements before substituting.
47
Closest known dimensional difference: height +6 mm. Verify application-specific requirements before substituting.
48
Closest known dimensional difference: height -5.1 mm. Verify application-specific requirements before substituting.
49
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
50
Closest known dimensional difference: height -6.9 mm. Verify application-specific requirements before substituting.
51
Closest known dimensional difference: height -18.3 mm. Verify application-specific requirements before substituting.
52
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
53
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
54
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
55
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
56
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
57
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
58
Closest known dimensional difference: height -8.6 mm. Verify application-specific requirements before substituting.
59
Closest known dimensional difference: height -7.4 mm. Verify application-specific requirements before substituting.
60
Closest known dimensional difference: height -13.7 mm. Verify application-specific requirements before substituting.