Bosch 3422 oil filter matches
Compare Bosch 3422 against compatible oil filters from other brands. Review thread size, gasket dimensions, height, valve behavior, and fitment notes before substituting. This is a research tool, not an automatic guarantee of fitment.
Before substituting: verify filter style, thread size or cartridge dimensions, gasket dimensions, height and clearance, bypass behavior, and your engine or equipment requirements.
Best equivalent matches
Select up to 4 filters, then click Compare to view their specs next to the searched filter. How matching is scored.
60 compatible options
| Specification | Searched filter Bosch 3422 Reference filter | Purolator PL20195Best Match SAFE | SAFE | SAFE | SAFE |
|---|---|---|---|---|---|
| Thread size | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 | 3/4-16 |
| Gasket OD | 70 mm | 69.4 mm | 71.1 mm | 71.1 mm | 71 mm |
| Gasket ID | 61 mm | 61.7 mm | 62.5 mm | 62.5 mm | 62 mm |
| Can OD | 75.01 mm | 75.69 mm | 74.7 mm | 75.794 mm | 74.19 mm |
| Height | 120.4 mm | 120.4 mm | 124.7 mm | 125.019 mm | 120.65 mm |
| Internal bypass valve | Yes | Yes | Yes | Yes | Yes |
| Bypass PSID | 12 - 15 | 12 - 15 | 12 | 12 | 8 - 11 |
| Anti-drainback valve | Yes | Yes | Yes | Yes | Yes |
Other suitable matches
Sorted best-fit first. Dot rating summarizes relative fit without exposing the raw score. How matching is scored.
13
Closest known dimensional difference: height +2.6 mm. Verify application-specific requirements before substituting.
14
Closest known dimensional difference: height +1.6 mm. Verify application-specific requirements before substituting.
15
Closest known dimensional difference: height -4.2 mm. Verify application-specific requirements before substituting.
16
Large bypass PSI mismatch: 16.5 psi
17
Closest known dimensional difference: height -1.4 mm. Verify application-specific requirements before substituting.
18
Closest known dimensional difference: height -39.2 mm. Verify application-specific requirements before substituting.
19
Closest known dimensional difference: height -51.6 mm. Verify application-specific requirements before substituting.
20
Closest known dimensional difference: height -32.8 mm. Verify application-specific requirements before substituting.
21
Closest known dimensional difference: height -35.4 mm. Verify application-specific requirements before substituting.
22
Closest known dimensional difference: height -44.4 mm. Verify application-specific requirements before substituting.
23
Closest known dimensional difference: height -42.4 mm. Verify application-specific requirements before substituting.
24
Closest known dimensional difference: height +9.8 mm. Verify application-specific requirements before substituting.
25
Large bypass PSI mismatch: 16.5 psi
26
Closest known dimensional difference: height -6.4 mm. Verify application-specific requirements before substituting.
27
Closest known dimensional difference: height +16 mm. Verify application-specific requirements before substituting.
28
Closest known dimensional difference: height -34.3 mm. Verify application-specific requirements before substituting.
29
Closest known dimensional difference: height -34 mm. Verify application-specific requirements before substituting.
30
Closest known dimensional difference: height -33.9 mm. Verify application-specific requirements before substituting.
31
Closest known dimensional difference: height -33.9 mm. Verify application-specific requirements before substituting.
32
Closest known dimensional difference: height -30.8 mm. Verify application-specific requirements before substituting.
33
Closest known dimensional difference: height -35.1 mm. Verify application-specific requirements before substituting.
34
Closest known dimensional difference: height -51.6 mm. Verify application-specific requirements before substituting.
35
Closest known dimensional difference: height -51.6 mm. Verify application-specific requirements before substituting.
36
Closest known dimensional difference: height -33.9 mm. Verify application-specific requirements before substituting.
37
Closest known dimensional difference: height -32.8 mm. Verify application-specific requirements before substituting.
38
Closest known dimensional difference: height -33.9 mm. Verify application-specific requirements before substituting.
39
Closest known dimensional difference: height -30.8 mm. Verify application-specific requirements before substituting.
40
Closest known dimensional difference: height -61.9 mm. Verify application-specific requirements before substituting.
41
Closest known dimensional difference: height -61.7 mm. Verify application-specific requirements before substituting.
42
Closest known dimensional difference: height -33.9 mm. Verify application-specific requirements before substituting.
43
Closest known dimensional difference: height -30.8 mm. Verify application-specific requirements before substituting.
44
Closest known dimensional difference: height -33.9 mm. Verify application-specific requirements before substituting.
45
Closest known dimensional difference: height -26.4 mm. Verify application-specific requirements before substituting.
46
Closest known dimensional difference: height -9.3 mm. Verify application-specific requirements before substituting.
47
Large bypass PSI mismatch: 18.5 psi
48
Large bypass PSI mismatch: 16.5 psi
49
Closest known dimensional difference: height -21.9 mm. Verify application-specific requirements before substituting.
50
Closest known dimensional difference: height -21.9 mm. Verify application-specific requirements before substituting.
51
Closest known dimensional difference: height -6.4 mm. Verify application-specific requirements before substituting.
52
Large bypass PSI mismatch: 16.5 psi
53
Large bypass PSI mismatch: 17.5 psi
54
Closest known dimensional difference: height +16 mm. Verify application-specific requirements before substituting.
55
Closest known dimensional difference: height +13.7 mm. Verify application-specific requirements before substituting.
56
Closest known dimensional difference: height -41.7 mm. Verify application-specific requirements before substituting.
57
Closest known dimensional difference: height -25.2 mm. Verify application-specific requirements before substituting.
58
Closest known dimensional difference: height -33.9 mm. Verify application-specific requirements before substituting.
59
Closest known dimensional difference: height +11.1 mm. Verify application-specific requirements before substituting.
60
Closest known dimensional difference: height -29.6 mm. Verify application-specific requirements before substituting.