LUBER-FINER HP1 vs Fleetguard LF3466: Oil Filter Compatibility

Compare LUBER-FINER HP1 and Fleetguard LF3466 oil filters by compatibility, dimensions, thread size, gasket fit, bypass valve, anti-drainback valve status, and match confidence. Use this comparison as a fitment review, not as an automatic substitution guarantee. Both use a 3/4-16 thread.

Quick verdict

COMPATIBLEMatch score: 89

Closest known dimensional difference: height -4.1 mm. Verify application-specific requirements before substituting.

  • Thread size is the first hard-fit check for any comparison of spin-on filters.
  • Gasket OD and gasket ID are the most important seal-related dimensions.
  • Height differences can matter for clearance even when thread and gasket fit appear close.
  • Bypass and anti-drainback differences may be important, depending on the application.

LUBER-FINER HP1 and Fleetguard LF3466 specifications

How matching is scored
Specification
LUBER-FINER HP1
Fleetguard LF3466
Thread size3/4-16UNF3/4-16 UNF-2B
Gasket OD70 mm71.98 mm
Gasket ID61 mm62.53 mm
Can OD93 mm94 mm
Height146.05 mm142 mm
Internal bypass valveYesYes
Bypass PSID2223.21
Anti-drainback valveYesYes

What matters in this specific comparison

Thread size matches: both are 3/4-16.

Gasket OD differs by 2 mm (LUBER-FINER HP1: 70 mm, Fleetguard LF3466: 71.98 mm).

Gasket ID differs by 1.5 mm (LUBER-FINER HP1: 61 mm, Fleetguard LF3466: 62.53 mm).

LUBER-FINER HP1 is 4.1 mm taller (LUBER-FINER HP1: 146.05 mm, Fleetguard LF3466: 142 mm) -- check clearance before substituting.

Can OD differs by 1 mm (LUBER-FINER HP1: 93 mm, Fleetguard LF3466: 94 mm).

Both open their bypass valve in a comparable range: LUBER-FINER HP1 at 22-22 psi, Fleetguard LF3466 at 23.21-23.21 psi -- these ranges do not overlap.

Open related filters

Before substituting, verify thread fit, gasket sealing dimensions, height clearance, bypass behavior, and anti-drainback requirements for your specific application.